Hi, Guest!
  • dari 4 halaman

Jual Beli Produk Network Analyzer

Zentian Environmental Quality Monitoring System EQMS-3000

Zentian Environmental Quality Monitoring System EQMS-3000

Network Analyzer
EQMS-3000 Environmental Quality Monitoring SystemProduct Description :EQMS-3000 is an online particulate monitoring system, which realizes integration of multi-parameter monitoring technique and solves technical problem of the uncontrolled emission. It is designed for construction sites, roads, living areas, factory sector, tourism, waste incineration plants and other construction sites and production situations. It can meet the intensive supervision and execution for environment protection bureau, through real time monitoring, snapping exceed standard occasions, counting and analyzing data graph, and realizing online dust monitoring and management.FeaturesSupporting map accurate navigation andpositioning, remote video surveillanceAutomatic Alarming reminds on-site workersSmart contrast providing project and regional dynamic analysis.Joint prevention and control, open-sharing platformSpecification : Noise  Range  30dB ~ 130dB (A) Noise Frequency  20Hz ~ 12.5kHz Noise Error  ± 0.5dB Particles Range  0.01mg/m3~10mg/m3 Particles Resolution  0.01mg / m3 Winds Range  0 ~ 50m/s Winds Accuracy  ± 0.5m/s Humidity  Range  0 ~ 100% RH Temperature  Range  -50℃~ + 100℃ Camera Resolution  1280 × 960 Camera Enclosure Rating  IP66 Camera Angle  360 °without dead angle Output Interface  RS485 / Ethernet, 3G optional Working Temperature  -30℃~ + 60℃ The system consists of monitoring equipment, cloud data management platform and client terminal. The Diagram of whole monitoring network is as follows:
Harga
Hubungi Kami
Min. Order
1 buah

  • PT. MITRA KATIGA SEJAHTERA Jual Peralatan Monitoring Lingkungan : STAPLEX/ DELTA OHM/ E INSTRUMENT/ HAZ DUST/ SHINAGAWA/ AQUALYTIC/ WILDCO/ ASSEMBLAD/ AIRMETRIC/ KITAGAWA

    Jakarta Timur • Jakarta • Indonesia
Lutron RGB-100 2 Color Analyzer, Probe + Meter

Lutron RGB-100 2 Color Analyzer, Probe + Meter

Network Analyzer
Lutron RGB-1002 COLOR ANALYZER, probe + meterDescription :SERIES Color Analyzer COLOR ANALYZER, probe + meter, RS232 Model : RGB-1002 * Measuring sample : no lighting sample(textiles, paper, leathers...).* Measurement value : RGB value, HSL value (Hue/Saturation/Luminance). * R(Red) value : 0 to 1023.                 G(Green) value : 0 to 1023. B(Blue) value : 0 to 1023. * 45o /0o color measuring geometry. * Used the spectral analysis method to determine the color of the sample. * Complete set included the color probe and the meter, show RGB or HSL value at same time. * RS232 computer interface. * Power : 006P DC 9V battery. * Meter size : 203 x 76 x 38 mm.METODE PEMBAYARAN :Pembayaran dapat dilakukan dengan cara Cash On Delivery / Transfer Bank. * C.O.D. ( Cash On Delivery / Bayar ditempat) Khusus untuk wilayah " Jakarta" kami melayani pemesanan dengan cara pembayaran di tempat anda, Prosesnya :1. Pesanan anda kami antar ke tempat anda2. Setelah anda terima silahkan cek kelengkapan dan kualitas barang3. Bila sudah ' OK' dan tidak ada masalah baru dibayar Pembayaran ditempat bisa dalam bentuk tunai ataupun Transfer . MITRA LASER bergerak dalam bidang penjualan Alat Survey, Digital Instrument, GPS (Global Positioning System), Surveying Instruments, Test and Measurement, Radio Komunikasi dan Satelite Communication, Telecommunication, Peralatan Marine/Kelautan, Alat Teknik, Alat Ukur/Uji Beton, Perkakas dan Peralatan Geologi.  Office :MITRA LASERJalan Cipto Mangunkusumo ( H.Mencong ) , Mahkota Simprug Blok B14 No. 6 Tangerang selatan, 15153Untuk info dan harga terbaik, silahkan hubungi :Mr.Rian HadiantoHP : 0811.2348.415 / 0813.9839.0838 / 0859.2001.5115Fax : 021-29040157BB PIN: 5EBFE32A, 51836708WA : 0811.2348.415 / 0813.9839.0838 / 0859.2001.5115Email: mitralaserstore@gmail.com / mitralaser21@gmail.com
Harga
Hubungi Kami
Min. Order
1 buah

  • Surveying Instruments, Alat Survey, Radio Komunikasi, GPS, Alat Teknik Sipil

    Tangerang Selatan • Banten • Indonesia
Power Network Analyzer Dynamic Signal Analyzer Data Acquisition

Power Network Analyzer Dynamic Signal Analyzer Data Acquisition

Network Analyzer
Monitoring System ï ¿ ½ Model ï ¿ ½ 7200A Portable Balancer - Tracking filter type balancer also available as a stroboscopic balance without a photo sensor - Equipped with a FFT function and an automatic sampling function as afrequency analyzer and printable on the built-in printer - Balancer Model-7200A - Extension cable for the pickup 30 meters long ( with a cable drum) - Electro-dynamic pickup ( selectable from S2037F-100, B9200, I-544) ï ¿ ½ Carrying bag ï ¿ ½ Stroboscope ï ¿ ½ Reflective type photosensor ( optional) Applicable vibration pickup : electro-dynamic vibration velocity pickup ( Three types of pickup below are selectable by a trim switch.) ï ¿ ½ MODEL-2009 : Sensitivity; 10mV/ mm/ sInput impedance; 10kï ¿ ½ ï ¿ ½ B-9200 : Sensitivity; 19.7mV/ mm/ sInput impedance; 10kï ¿ ½ ï ¿ ½ I-544 : Sensitivity; 2.5mV/ mm/ sInput impedance; 1Mï ¿ ½ Vibration pickup input : Channel A or Channel B ( selectable) Rotational signal input : 0-5V rise-up signal of 1 pulse per revolution For indication of revolution and phase reference of the tracking filter. AC OUT : Vibration waveform output ï ¿ ½ 2V/ FSOutput impedance 100ï ¿ ½ Stroboscope output : for the attached stroboscope ( turned on and off by a switch) Display : Digital LED display and indicators ï ¿ ½ r.p.m. Indication / 500-10, 000rpm Resolution 1rpm ï ¿ ½ Indication of FIL OUT vibration value / Overall vibration value ï ¿ ½ Indication of FIL IN vibration value / Filter pass value in Tracking or Man. Tune mode ï ¿ ½ Phase angle indication / 0 to 359 degrees angle between the rise of a revolution pulse and a positive peak of the vibration waveform of the component of revolution ï ¿ ½ LOCK indicator: Lights when the balancer is in synchronism with the revolution signal or the internal oscillator. ï ¿ ½ INPUT SEL indicator / Shows an input channel that is under measurement ï ¿ ½ Unit indicator: Lights to indicate an acceleration, velocity, or displacement Analog meter : 0-1 scale over 0-3 scale ï ¿ ½ FIL IN mode : Shows the filter pass value in the Tracking or Man.Tune mode ï ¿ ½ FIL OUT mode : Shows an overall vibration value Printer : A built- in thermal printer ï ¿ ½ PRINT : Prints out the result of current measurement at any timing ï ¿ ½ ANALYZE : Captures vibration waveforms, performs FFT on them, and prints out the resulting graph and a list of up to five peaks. ï ¿ ½ AUTO LOG : Prints out the result of measurement of a selected channel under the specified conditions. Range of vibration measuring frequency : 10Hz~ 200Hz( ï ¿ ½ 0.5dB) Full scale range ( 10 dB step) ï ¿ ½ Displacement : 1, 3.16, 10, 31.6, 100 ï ¿ ½ 1/ 100mm( P-P) FS ï ¿ ½ Velocity : 1, 3.16, 10, 31.6, 100 mm/ s ( Peak) Full scale ï ¿ ½ Acceleration : 1, 3.16, 10, 31.6 , 100 m/ s2( Peak) Full scale Stroboscopic balancer function : Flashes at a vibration phase filtered with a ( FILTER: MAN.TUNE) frequency of theinternal oscillator as the central frequency. ( 500-10, 000rpm) . Automatic capture and print function : Automatically captures vibration data according to OR of an r.p.m. change pitch and a time lapse pitch and prints out it together with time data. Tracking filter function : Automatic tuning with the signal from the revolution sensor by the tracking filter Power supply : AC100Vï ¿ ½ 10V, Normally 1A or less, 2A fuse Dimensions and weight : ( W) 300ï ¿ ½ ( H) 123ï ¿ ½ ( D) 230mm, 4.5kg. Kunjungi Web kami juga di : http: / / vibrasindo.com Vibrasindo Kontak Person: Fikri ( 0815 614 1954, 0811 893 101) . Alamat: Jl. Pahlawan Revolusi No. 22B. Telp. + 62-21-8611 131, 8611 259, 8611 444, 8611449 Fax: + 62-21-8611 207. Email: sales@ vibrasindo.com Website: www.vibrasindo.com Monitoring System ï ¿ ½ Model ï ¿ ½ 7200A Portable Balancer - Tracking filter type balancer also available as a stroboscopic balance without a photo sensor. - Equipped with a FFT function and an automatic sampling function as afrequency analyzer and printable on the built-in printer. - Balancer Model-7200A. - Extension cable for the pickup 30 meters long ( with a cable drum) . - Electro-dynamic pickup ( selectable from S2037F-100, B9200, I-544) ï ¿ ½ Carrying bag ï ¿ ½ Stroboscope ï ¿ ½ Reflective type photosensor ( optional) Applicable vibration pickup : electro-dynamic vibration velocity pickup ( Three types of pickup below are selectable by a trim switch.) ï ¿ ½ MODEL-2009 : Sensitivity; 10mV/ mm/ sInput impedance; 10kï ¿ ½ ï ¿ ½ B-9200 : Sensitivity; 19.7mV/ mm/ sInput impedance; 10kï ¿ ½ ï ¿ ½ I-544 : Sensitivity; 2.5mV/ mm/ sInput impedance; 1Mï ¿ ½ Vibration pickup input : Channel A or Channel B ( selectable) Rotational signal input : 0-5V rise-up signal of 1 pulse per revolution For indication of revolution and phase reference of the tracking filter. AC OUT : Vibration waveform output ï ¿ ½ 2V/ FSOutput impedance 100ï ¿ ½ Stroboscope output : for the attached stroboscope ( turned on and off by a switch) Display : Digital LED display and indicators ï ¿ ½ r.p.m. Indication / 500-10, 000rpm Resolution 1rpm ï ¿ ½ Indication of FIL OUT vibration value / Overall vibration value ï ¿ ½ Indication of FIL IN vibration value / Filter pass value in Tracking or Man. Tune mode ï ¿ ½ Phase angle indication / 0 to 359 degrees angle between the rise of a revolution pulse and a positive peak of the vibration waveform of the component of revolution ï ¿ ½ LOCK indicator: Lights when the balancer is in synchronism with the revolution signal or the internal oscillator. ï ¿ ½ INPUT SEL indicator / Shows an input channel that is under measurement ï ¿ ½ Unit indicator: Lights to indicate an acceleration, velocity, or displacement Analog meter : 0-1 scale over 0-3 scale ï ¿ ½ FIL IN mode : Shows the filter pass value in the Tracking or Man.Tune mode ï ¿ ½ FIL OUT mode : Shows an overall vibration value Printer : A built- in thermal printer ï ¿ ½ PRINT : Prints out the result of current measurement at any timing ï ¿ ½ ANALYZE : Captures vibration waveforms, performs FFT on them, and prints out the resulting graph and a list of up to five peaks. ï ¿ ½ AUTO LOG : Prints out the result of measurement of a selected channel under the specified conditions. Range of vibration measuring frequency : 10Hz~ 200Hz( ï ¿ ½ 0.5dB) Full scale range ( 10 dB step) ï ¿ ½ Displacement : 1, 3.16, 10, 31.6, 100 ï ¿ ½ 1/ 100mm( P-P) FS ï ¿ ½ Velocity : 1, 3.16, 10, 31.6, 100 mm/ s ( Peak) Full scale ï ¿ ½ Acceleration : 1, 3.16, 10, 31.6 , 100 m/ s2( Peak) Full scale Stroboscopic balancer function : Flashes at a vibration phase filtered with a ( FILTER: MAN.TUNE) frequency of theinternal oscillator as the central frequency. ( 500-10, 000rpm) . Automatic capture and print function : Automatically captures vibration data according to OR of an r.p.m. change pitch and a time lapse pitch and prints out it together with time data. Tracking filter function : Automatic tuning with the signal from the revolution sensor by the tracking filter Power supply : AC100Vï ¿ ½ 10V, Normally 1A or less, 2A fuse Dimensions and weight : ( W) 300ï ¿ ½ ( H) 123ï ¿ ½ ( D) 230mm, 4.5kg. Kunjungi Web kami juga di : http: / / vibrasindo.com Vibrasindo Kontak Person: Fikri ( 0815 614 1954, 0811 893 101) . Alamat: Jl. Pahlawan Revolusi No. 22B. Telp. + 62-21-8611 131, 8611 259, 8611 444, 8611449 Fax: + 62-21-8611 207. Email: sales@ vibrasindo.com Website: www.vibrasindo.com Monitoring System ï ¿ ½ Model ï ¿ ½ 7200A Portable Balancer - Tracking filter type balancer also available as a stroboscopic balance without a photo sensor. - Equipped with a FFT function and an automatic sampling function as afrequency analyzer and printable on the built-in printer. - Balancer Model-7200A. - Extension cable for the pickup 30 meters long ( with a cable drum) . - Electro-dynamic pickup ( selectable from S2037F-100, B9200, I-544) ï ¿ ½ Carrying bag ï ¿ ½ Stroboscope ï ¿ ½ Reflective type photosensor ( optional) Applicable vibration pickup : electro-dynamic vibration velocity pickup ( Three types of pickup below are selectable by a trim switch.) ï ¿ ½ MODEL-2009 : Sensitivity; 10mV/ mm/ sInput impedance; 10kï ¿ ½ ï ¿ ½ B-9200 : Sensitivity; 19.7mV/ mm/ sInput impedance; 10kï ¿ ½ ï ¿ ½ I-544 : Sensitivity; 2.5mV/ mm/ sInput impedance; 1Mï ¿ ½ Vibration pickup input : Channel A or Channel B ( selectable) Rotational signal input : 0-5V rise-up signal of 1 pulse per revolution For indication of revolution and phase reference of the tracking filter. AC OUT : Vibration waveform output ï ¿ ½ 2V/ FSOutput impedance 100ï ¿ ½ Stroboscope output : for the attached stroboscope ( turned on and off by a switch) Display : Digital LED display and indicators ï ¿ ½ r.p.m. Indication / 500-10, 000rpm Resolution 1rpm ï ¿ ½ Indication of FIL OUT vibration value / Overall vibration value ï ¿ ½ Indication of FIL IN vibration value / Filter pass value in Tracking or Man. Tune mode ï ¿ ½ Phase angle indication / 0 to 359 degrees angle between the rise of a revolution pulse and a positive peak of the vibration waveform of the component of revolution ï ¿ ½ LOCK indicator: Lights when the balancer is in synchronism with the revolution signal or the internal oscillator. ï ¿ ½ INPUT SEL indicator / Shows an input channel that is under measurement ï ¿ ½ Unit indicator: Lights to indicate an acceleration, velocity, or displacement Analog meter : 0-1 scale over 0-3 scale ï ¿ ½ FIL IN mode : Shows the filter pass value in the Tracking or Man.Tune mode ï ¿ ½ FIL OUT mode : Shows an overall vibration value Printer : A built- in thermal printer ï ¿ ½ PRINT : Prints out the result of current measurement at any timing ï ¿ ½ ANALYZE : Captures vibration waveforms, performs FFT on them, and prints out the resulting graph and a list of up to five peaks. ï ¿ ½ AUTO LOG : Prints out the result of measurement of a selected channel under the specified conditions. Range of vibration measuring frequency : 10Hz~ 200Hz( ï ¿ ½ 0.5dB) Full scale range ( 10 dB step) ï ¿ ½ Displacement : 1, 3.16, 10, 31.6, 100 ï ¿ ½ 1/ 100mm( P-P) FS ï ¿ ½ Velocity : 1, 3.16, 10, 31.6, 100 mm/ s ( Peak) Full scale ï ¿ ½ Acceleration : 1, 3.16, 10, 31.6 , 100 m/ s2( Peak) Full scale Stroboscopic balancer function : Flashes at a vibration phase filtered with a ( FILTER: MAN.TUNE) frequency of theinternal oscillator as the central frequency. ( 500-10, 000rpm) . Automatic capture and print function : Automatically captures vibration data according to OR of an r.p.m. change pitch and a time lapse pitch and prints out it together with time data. Tracking filter function : Automatic tuning with the signal from the revolution sensor by the tracking filter Power supply : AC100Vï ¿ ½ 10V, Normally 1A or less, 2A fuse Dimensions and weight : ( W) 300ï ¿ ½ ( H) 123ï ¿ ½ ( D) 230mm, 4.5kg. Jakarta - Indonesia Phone : 021-29563045 ( hunting) Hp : 08156141954 Pin BB : 284152F7
Harga
Hubungi Kami
Min. Order
0 buah

  • PT VIBRASINDO - Condition Monitoring & PdM Solution

    Jakarta • DKI Jakarta • Indonesia
Sistem Monitoring Online

Sistem Monitoring Online

Network Analyzer
Monitoring System  Portable Balancer Model- 7135 " From field measurement to the output of work reports. Model- 7135 condenses functions and user- friendliness that enable efficient field balancing into a compact body" . " ( Simple balancing without the need of removal) Model- 7135 is a portable balancer that can be easily rebalanced with the target rotary machine installed. The model provides comprehensive balancing when a dynamic balancing test with a rotor alone is impossible or after its assembly is completed, and other mobility performance that enables field work more efficiently. It is automatically tuned with a tracking filter, this facilitating measurement work" . " Outstanding ( user- friendliness with special- purpose software) " . Special- purpose software " Balance One" enables very efficient work in combination with a notebook PC. Balancing can be easily done by operating the keys while watching the screen of the notebook PC. What is more, the model comes with a report format ( Excel- compatible) , thus enabling the data to be used for reporting purposes. All you have to do then is to go back to the office and print them out. The work is now complete. The model is outstandingly user- friendly, with the capability of integrated processing from beginning to end. " ( Various handy functions that increase its versatility) Model 7135 is compatible with rotary machines from 180 to 30, 000 rpm as a field balancer. It also allows users to select from among an acceleration sensor, speed sensor, and non- contact displacement sensor. It incorporates a vector output as well, thus enabling polarograms with an X- Y recorder and offering high versatility as a vibration gage, vibration monitor, and tachometer. Specifications: Applicable detectors - [ Acceleration Pickup] ; - 1V/ 10( m/ s 2 ) ( OP: 0.5 to 5V/ 10( m/ s 2 ) ) 2CH* ; - Capability to incorporate a power supply for servo ; Pickup or amplifier- equipped Pickup [ Velocity Pickup] - 80mV/ cm/ s ( OP: 50 to 500mV/ cm/ s) 2CH* - Capability of incorporating a low- range compensation circuit [ Displacement Pickup] - 4V/ mm ( OP: 2 to 20V/ mm) 2CH* Capability of incorporating a drive power supply for non- contact Pickup Note: When in a standard configuration, the model is for channel 6 " speed Pickup." Number of input channels - 6 channels at the maximum. Channel numbers for each Pickup can be changed from channel 1 to 6. - With a channel selector, you can select and display any channel. Rotary pulse input Photo sensor or pulse signals 0 to + 12V, pulse width 10 s or more, with a + 12V power supply for driving the photo sensor Vibration indication range 0.02 to 1000 m ( P- P) , resolution: 0.01 mp- p ( high- sensitivity range) Measurement range 3.16, 10, 31.6, 100, 316, 1000 m m ( P- P) / FS Frequency range 3 to 500 Hz 1 dB ( depending on the frequency characteristics of the Pickup) Tachometer indicator 180- 30, 000 rpm; resolution: 1 rpm OVER and LOW lndicator Indicators for appropriate range indication Outputs [ Waveform monitor output] 5V/ FS [ Vector output] 5VDC for both X and Y [ Amplitude DC output] 0 to + 5VDC [ Rotating speed DC output] 0 to 5VDC RS- 232C Capability of data reading the control of range and filter on a PC D- SUB 25pin connector Power supply 100V AC 10V, 1A or less Outside dimensions and weight 260 ( W) x 100 ( H) x 180 ( D) mm ( except for the lugs) , approx. 2.3kg Jakarta - Indonesia Phone : 021-29563045 ( hunting) Hp : 08156141954 Pin BB : 284152F7
Harga
Hubungi Kami
Min. Order
0 buah

  • PT VIBRASINDO - Condition Monitoring & PdM Solution

    Jakarta • DKI Jakarta • Indonesia
Condition Monitoring & Vibration Analysis Model ï ¿ ½ 1590

Condition Monitoring & Vibration Analysis Model ï ¿ ½ 1590

Network Analyzer
Monitoring System ï ¿ ½ Vibration Monitor Model ï ¿ ½ 1590 ï ¿ ½ Model- 1590- 01 is a 1- channel type vibration monitor using a non contact displacement sensor; ï ¿ ½ Model- 1590- 03 is designed to indicate the larger displacement of the two radical vibration displacements of a rotor, and also to give an alarm, when vibration exceeds the preset value; ï ¿ ½ Two high limits of alarming are provided. A delay timer for preventing wrong alarming is incorporated; Specifications: Measuring contents : 1590- 01, Seismic vibration displacement : 1590- 03, Indicating the larger displacement of the two radial displacements of a rotor. Frequency range : 1590- 01, 5Hz- 50Hx ï ¿ ½ 5% : 1590- 03, 2Hz- 100Hz ï ¿ ½ 5% Measuring range : 0- 600ï ¿ ½ mp- p/ FS Indicator scale : Same as the above. Minimum scale is 1/ 30 of FS and GAP 0- 4mmp- p. Signal input : Terminal on the rear panel. : Input sensitivity conforms to TQ402/ IQS452 Monitor output : 10Vp- p/ FS, Load: 500ï ¿ ½ max. : 1590- 01: Displacement wave signal, Terminal of the front panel. : 1590- 03: Displacement wave signal of X, Y direction. : BNC connector of the front panel. OK Monitor lamp : Lamp indication in normal ready condition. Relay contact output : SPDT( both ALERT and DENGER output) : Capacity AC: 220Vmax, 4Amax, 400VAmax. : DC: 110Vmax, 3Amax, 50Wmax. Alarm delay action : Auto resetting action, Delay 60sec. Recorder output : DC 4- 20mA, Load: 500ï ¿ ½ max. Signal input : Terminal on the rear panel. Power requirement : AC220V ï ¿ ½ 10% 50/ 60Hz 20VA max Temperature : Operating: 0- 50ï ¿ ½ C, Storage: - 20- + 70ï ¿ ½ C. Jakarta - Indonesia Phone : 021-29563045 ( hunting) Hp : 08156141954 Pin BB : 284152F7
Harga
Hubungi Kami
Min. Order
0 buah

  • PT VIBRASINDO - Condition Monitoring & PdM Solution

    Jakarta • DKI Jakarta • Indonesia
Vibration Analyzer

Vibration Analyzer

Network Analyzer
Getaran Analyzer ï ¿ ½ Model ï ¿ ½ 4035 Charge Amplifier: Model-4035 charge amplifier adalah untuk memperkuat sinyal-sinyal output secara langsung ditularkan dari jenis piezo-listrik, pickup untuk pengukuran tepat getaran. SPESIFIKASI: - Frekuensi Karakteristik: : 0.5Hz untuk 100KHz + 1, - 3dB : 1Hz untuk 50KHzï ¿ ½ 1dB : 5Hz untuk 20KHzï ¿ ½ 0.5dB - Sensitivitas Kendali Skala, Model 4035 ( Standard Version) : 1 V / 1pc sampai 10, 000pC Model 4035-01 ( Versi Sensitivitas tinggi) : 1 V / 0.1pC ke 1, 000pC. - Full-Range Model Skala-4035 ( Standard Version) adalah sebagai berikut: 1, 00 sampai 9.99pC / UNIT: 1, 3, 10, 30, 100, 300, 1000UNIT / FS 10, 0 untuk 99.9pC / UNIT: 0.1, 0.3, 1, 3, 10, 30, 100UNIT / FS ( di Nilai Dinyatakan di Panel itu) . 100 sampai 999pC / UNIT: 0, 01, 0, 03, 0, 1, 0, 3, 1, 3, 10UNIT / FS - Output Karakteristik. AC Output: : ï ¿ ½ 1V / FS Non-Distorsi Max. Output Voltage: 10V ï ¿ ½ ( Loaded Resistance: Lebih besar dari 10kï ¿ ½ ) DC Output: : 1VDC + / FS, 5mA Max. ( Untuk memanggil " Model-4035 - xx-D" ketika memesan) . - Tingkat Kebisingan: : 0.008PCrms + 0.005pCRMS per 1, 000pF sumber kapasitansi disebut masukan atau 5mVrms dimaksud output, yang lebih besar. - Keakuratan: : Dalam ï ¿ ½ 1, 5% sepanjang seluruh jajaran di 1, 000Hz dan pada 1, 000pF atau lebih rendah dalam kapasitas input. - Overload Indikasi: : The overload lampu peringatan lampu ketika melebihi. lingkup linier. - Suhu / Kelembaban Range: : - 20ï ¿ ½ C + 60ï ¿ ½ C ( 0, 05% / ï ¿ ½ C) , RH 90% atau lebih rendah. - Power Supply: : ï ¿ ½ 9V untuk ï ¿ ½ 15V, 20mA Max. - Dimensi dan Berat: : 34, 5 ( W) ï ¿ ½ 99 ( H) ï ¿ ½ 152 ( D) mm, 1, 000g. - Aksesoris Power Supply Unit: : Dimensi dan berat: 69 ( W) ï ¿ ½ 99 ( H) ï ¿ ½ 152 ( D) mm, 1, 000g. Model-4035 - 10M: : Untuk 100VAC, lengkap dengan sinyal CAL dan 10CH. Switching AC Meter, untuk 10CH Max. Model-4035 - 16 juta: : Untuk kedua 100VAC dan 12VDC. Distributor agent menjual service repair jasa perbaikan alat, Dosimeter, NDT Industrial, X-Ray Film Dryer, NDT Dryer, adhesion tester, PosiPen, measure coating thickness, coating thickness gauge, calibrtion standardfor coating thickness gauge, PosiPrinter, Fillet Weld Set, Digital Welding Gage, hi-lo Welding Gage, Mini Sub Socket Weld, Pipe Pit Gauge, Mini Fillet & Taper, bridge cam gage, Single Purpose HiLo, Pocket Bridge Cam, Flaw Detectors, Hardness Testers, Thickness Gauges, Probes, Ultrasonic Testing Machines, rightrax installed sensors, Remote Visual Inspection, Steel-Cord Conveyor Belts, Introcon belts, Pipe wall thinning, Weld location, Pipe blockages, Integrity in ammonia systems, Inspection of wood, Inspection of rubber, Inspection of composite materials, Magnetic Particle Equipment, mobile power packs, Blok calibration, Crack Comparator calibration, Digital Light Meter, gauss meter, Remote Cable Palm, Spray Gun, UV products for nondestructive testing, load measurement analysis, stress analysis, Load Shackles, Densitometer, dst. Jakarta - Indonesia Phone : 021-29563045 ( hunting) Hp : 08156141954 Pin BB : 284152F7
Harga
Hubungi Kami
Min. Order
0 buah

  • PT VIBRASINDO - Condition Monitoring & PdM Solution

    Jakarta • DKI Jakarta • Indonesia
Vibration Analyzer Model- 4409 Dynamic Amplifier

Vibration Analyzer Model- 4409 Dynamic Amplifier

Network Analyzer
Vibration Analyzer  Model- 4409 Dynamic Amplifier. " This amplifier system is used to input vibrating acceleration and sound noise into a data recorder using a piezoelectric accelerometer and a condenser microphone" " Designed for multi-channel vibration/ sound level measurement" Specification Applicable sensor Condenser Microphone PU SENS: 0.1Range 1.00-9.99mVrms/ Pa( = 0.1-1mVrms/ bar) 1 Range 10.0-99.9mVrms/ Pa( = 1-10mVrms/ bar) Piezoelectric Type Accelerometer PU SENS: 0.1Range 1.00-9.99pC/ UNIT maximum output 1000pC 1 Range 10.0-99.9pC/ UNIT maximum output 10, 000pC 10 Range 100-999pC/ UNIT maximum output 100, 000p Sound Level Measurement Measurement Range 50dBsL-130dBsL ( Case; PUSENS: 0.1& 70dBsL-130dBsL) Full Scale Range -40dB-0dB-+ 40dB 10dB Step 0dB= 90dBsL Frequency Response " LIN" : 2Hz-20kHz( 1dB) " A" Weighting : Conformance with JIS or IEC Vibration Measurement Measurement Range 0.01UNIT-100UNIT FS ( Case; PUSENS: 0.1& 0.1-100UNIT FS) Full Scale Range -40dB-0dB-+ 40dB 10dB Step 0dB= 1G Frequency Response 2Hz-20kHz( 1dB) Output BNC Connector 1V Full Scale Impedance 10k min Over Load Indicator Lit when the output voltage exceeding 1.4Vrms or exceeding the linear sphere. Level Meter Analog meter for Monitor output level, Max hold Cal signal 300 Hz 1% , sinusoidal wave, Output level Variable Temperature, Humidity 0-50 C 90% RH max Power Supply 12V DC( 10V-15V) , 2.5Atyp. 4Amax. Size Weight In case of 7CH Type 325( W) 221.5( H) 302( D) mm 11.5kg In case of 12CH Type 500( W) 221.5( H) 302( D) mm 17.5kg. Distributor agent menjual service repair jasa perbaikan alat, Online monitoring, condition monitoring, Oil analysis, Borescope, Vibration Analyzer, dst. Jakarta - Indonesia Phone : 021-29563045 ( hunting) Hp : 08156141954 Pin BB : 284152F7
Harga
Hubungi Kami
Min. Order
0 buah

  • PT VIBRASINDO - Condition Monitoring & PdM Solution

    Jakarta • DKI Jakarta • Indonesia
Amprobe IR-712 Infrared Thermometer

Amprobe IR-712 Infrared Thermometer

Network Analyzer
CALL:A.WIHARTA081294124885085778084789087784022201Karya Mandiri Instrument indonesia adalah supplier peralatan laboratorium baik eletronik maupun mekanik, serta berbagai macam instrument measurement, dengan didukung dari berbagai macam merk dari negara negara Eropa, US, dan beberapa negara di Asia seperti Korea, Japan dan Taiwan. Instrument yang kami sediakan seperti : Anemometer, Analitical Balance, Spectrophotometer, pHmeter, Laser survey, Micropipette, Peristaltic Pump, Flame photometer, Water bath heating cooling, Colorimeter, Water Strirer, Viscometer. Freezers, Refractometer, Polarimeter, Sound Level meter, Tachometer. Dll Kami juga menerima jasa service dan kalibrasi untuk peralatan laboratorium sesuai kemampuan kami.   The Amprobe IR-712, a 12: 1 spot to distance ratio infrared thermometer, offers best in class accuracy and response time with a temperature measurement range of 0° F to 1022° F or -18° C to 550° C. The IR-712 is specifically designed for HVAC/ R, electrical, industrial maintenance, automotive as well as quality control and fire prevention applications FEATURES 12: 1 Distance to Spot Ratio Temp Range of 0° F to 1022° F or -18° C to 550° C Precision accuracy and rapid response time Laser pointer, backlit dual LCD Display Auto display hold and MAX/ MIN memory Adjustable emissivity for measuring a variety of materials
Harga
Hubungi Kami
Min. Order
0 buah

  • Karya Mandiri Instrument Indonesia

    Jakarta Timur • DKI Jakarta • Indonesia
IRtek IR50i

IRtek IR50i

Network Analyzer
CALL:A.WIHARTA081294124885085778084789087784022201Karya Mandiri Instrument indonesia adalah supplier peralatan laboratorium baik eletronik maupun mekanik, serta berbagai macam instrument measurement, dengan didukung dari berbagai macam merk dari negara negara Eropa, US, dan beberapa negara di Asia seperti Korea, Japan dan Taiwan. Instrument yang kami sediakan seperti : Anemometer, Analitical Balance, Spectrophotometer, pHmeter, Laser survey, Micropipette, Peristaltic Pump, Flame photometer, Water bath heating cooling, Colorimeter, Water Strirer, Viscometer. Freezers, Refractometer, Polarimeter, Sound Level meter, Tachometer. Dll Kami juga menerima jasa service dan kalibrasi untuk peralatan laboratorium sesuai kemampuan kami.   IR50i Infrared Thermometer support K Type Thermocouple Measurement Range : -60º C ~ 500º C ( -76º F ~ 932º F) Distance : Spot : 11 : 1 Resolution : 0.1º Accuracy : ± 1º C ( ± 1.8º F) for 15º C ~ 35º C; ± 2% of reading or ± 2º C ( ± 4º F) whichever is greater Emissivity : adjustable 0.10 ~ 1.00 Response Time : 1 second Spectral Response : 8 ~ 14µ m Laser Pointer : Single, Class II, up to 1mW Thermocouple : K type; range : -64º C ~ 1400º C ( -83.2º F ~ 1999º F) ; accuracy : ± 1% of reading or ± 1º C ( ± 1.8º F) whichever is greater Power : 2 x 1.5V ( AAA battery) Size : H175 x D39 x W72 mm Weight : 179g Standard Accessories : Operation Manual, Batteries, Warranty Card, Certificate of Product Conformance Optional Accessories : Thermocouple Probe, Soft Case, Hard Case, Calibration Certificate
Harga
Hubungi Kami
Min. Order
0 buah

  • Karya Mandiri Instrument Indonesia

    Jakarta Timur • DKI Jakarta • Indonesia
Alat Kelistrikan Kyoritsu 8128 Load Current Clamp Sensor

Alat Kelistrikan Kyoritsu 8128 Load Current Clamp Sensor

Network Analyzer
NAMA         :A.WIHARTAPHone        :081294124885  .085778084789  .0877840222201PIN BB       : D3AAE606Whatsapp   :085778084789Conductor size ¦ 24 Rated current AC 5A ( Max.50A) Output voltage AC 50mV/ 5A [ Max.500mV/ 50A] ( AC 10mV/ A) Accuracy | ± 0.5% rdg± 0.1mV ( 50/ 60Hz) | ± 1.0% rdg± 0.2mV ( 40Hz~ 1kHz) Phase Shift within ± 2.0º ( 45~ 65Hz) Withstand voltage AC 3540V for 5 seconds Cable length Approx. 3m Output connector MINI DIN 6pin Operating temperature ranges 0~ 50º C, less than 85% RH ( without condensation) Output impedance Approx. 20© Applicable standards IEC 61010-1: 2001, IEC 61010-2-032: 2002, CAT.III 300V pollution degree 2 Dimensions 100( L) x 60( W) x 26( D) mm Weight Approx.160g Accessories 9095 ( Portable case) , Instruction manual, Cable marker Option 7146 ( Banana ¦ 4 adjuster plug) 7185 ( Extension Cable)Tags:Kyoritsu Murah,Kyoritsu Jakarta, Agen Kyoritsu,Kyoritsu Indonesia,Kyoritsu Distributor,Kyoritsu Berkualitas, Promo Kyoritsu,Supplier Kyoritsu ,Kyoritsu Refair.Agen Murah, Distributor Indonesia, BERBAGAI Merek alat alat Laboratorium Dan instrument sbb: RION, BestScope, Hioki, Extech, Davis, Weather Station, Fluke ,, Boeco, Constant, Hach, Brookfield, Irtek, GE Druck, Kett, Kyoritsu, Kern, Lutron, megger, Nytech, Ohaus, Schoot Instrumen, Hanna Instrument, Atago, AMPROBE, Ebro, Dwyer, Memmert, Eutech, Ika, Kanomak,
Harga
Hubungi Kami
Min. Order
1 buah

  • Karya Mandiri Instrument Indonesia

    Jakarta Timur • DKI Jakarta • Indonesia
TEKTRONIX – PA3000

TEKTRONIX – PA3000

Network Analyzer
Product Description The Tektronix PA3000 is a one- to four-channel power analyzer that’s ready to meet the challenges of testing today’s single- and multi-phase, high efficiency power conversion products and designs.  Use it to quickly visualize, analyze, and document power efficiency, energy consumption, and electrical performance to the latest regional and international standards, including Level VI, Energy Star, CEC, IEC 62301, CQC-3146, and more. Specification Features Benefits One- to four-channel AC/DC power analysis Optimized for testing multiple stages of single- and multi-phase power conversion systems 10 mW standby power measurement Supports latest requirements for low standby power designs; full IEC 62301 compliance testing 1 MHz bandwidth Supports complete harmonic analysis of designs with high fundamental frequencies ±0.04% basic voltage and current accuracy Supports testing to Level VI efficiency standards for external AC/DC power supplies Continuous 1 MS/s sampling rate Enables accurate and gap-less input power analysis on non-sinusoidal signals events PWRVIEW Software Automates instrument setup, data collection, and report generation for key applications Full color, graphical display Offers intuitive readouts of measured values, waveforms, harmonics, and energy integration plots
Harga
Hubungi Kami
Min. Order
1 buah

  • PT. MADIRI MULTI KREASI. No.Tlp : 021-6230 5566/ 0813 1600 6033 / 0812 9436 9944

    Jakarta Barat • DKI Jakarta • Indonesia
TEKTRONIX – OM4000

TEKTRONIX – OM4000

Network Analyzer
Product Description The OM4245 Coherent Optical Modulation Analyzer provides the ultimate flexibility in your system configuration by being tightly integrated with the DP070000SX Series 70 GHz real-time oscilloscopes and the DSA8300 Series 70 GHz equivalent-time oscilloscope. The OM4245 uses coherent detection to acquire fiber signals carrying up to 80 GBaud, then analyzes both modulation and source properties using the power of optical industry tested DSP. It presents a rich library of results and graphical plots with the ease of use offered by a dedicated graphical user interface. Dynamic and feature-rich MATLAB integration provides the ultimate in analysis system customization and extensibility. Specification Features Benefits Complete characterization of signals up to 80 GBaud with the DPO70000SX Series 70 GHz real-time oscilloscope and the DSA8300 Series 70 GHz equivalent-time oscilloscope Tight integration with both real-time and equivalent-time Tektronix Oscilloscopes for calibrated system performance Support for multi-carrier systems, including 400G superchannels Performs automated testing of multi-carrier systems and provides integrated channel measurement results for fast analysis Optimal signal processing algorithms for optical signals No need to be a signal processing expert to get the best results Detailed analysis of phase or amplitude-modulated signals Q-factor plots provide BER vs. decision threshold and SNR Support for dual polarization transmission See tributary polarization state and extinction ratio Compatible with 3rd Party Coherent Receivers OM2210 provides flexibility to support future & existing needs Direct MATLAB Interface Enables quick, customizable analysis based on any variable Two narrow linewidth ECDL lasers built into system Assists in rapid calibration verification
Harga
Hubungi Kami
Min. Order
1 buah

  • PT. MADIRI MULTI KREASI. No.Tlp : 021-6230 5566/ 0813 1600 6033 / 0812 9436 9944

    Jakarta Barat • DKI Jakarta • Indonesia
TEKTRONIX – TLA7SA00

TEKTRONIX – TLA7SA00

Network Analyzer
Product Description The TLA7SA00 Series logic protocol analyzer modules provide an innovative approach to PCI Express validation that spans all layers of the protocol from the physical layer to the transaction layer. Feature rich software provides improved information density for viewing statistical summary and protocol analysis using innovative Transaction and Summary Profile windows. Hardware capabilities including hardware acceleration, OpenEYE, ScopePHY, and FastSYNC provide fast access to data and helps shorten the time it takes to build confidence in the test system. Powerful trigger and filtering capabilities provide the ability to quickly focus on the data of interest. A complete suite of probing solutions targeted for various form factors and applications. Specification Features Benefits OpenEYE Equalization You can probe anywhere on the bus thanks to OpenEYE Technology with automatic tuning equalization circuitry ScopePHY Probing Quickly gain confidence that your setup is correct and your PCI signal meets probe input requirements by routing any signal directly to a high bandwidth Oscilloscope FastSYNC Guaranteed resynchronization time to be <12 FTS1 (PCIe2) or <4 FTS2 (PCIe3) regardless of the Electrical Idle time for Advanced Power State Management performance Data Storage and HW Accelerated Search Get access to data and execute searches on any pattern in seconds regardless of record length Comprehensive Trigger System Quickly build a trigger definition to trigger on the most elusive PCIe events occurring on Link Innovative Data Views Get unprecedented visibility into your data from Protocol to Physical layer Observe and Analyze Link based behavior of protocol elements (transactions, packets, fields, ordered sets) with the Transaction Window Get high-ground visibility of system issues involving flow control with Unique Bird’s EyE View integrated into the Transaction window Get a data rich statistics based view of all PCIe protocol elements through summary Profile Window Get insight into physical layer details with the unique Listing window showing packet details as well as lane by lane symbol decode MultiBus Correlation Get full system visibility of multiple busses (DDR, PCIe, QPI, etc) as well as other system level activity through the legacy power of the Logic Analyzer functionality
Harga
Hubungi Kami
Min. Order
1 buah

  • PT. MADIRI MULTI KREASI. No.Tlp : 021-6230 5566/ 0813 1600 6033 / 0812 9436 9944

    Jakarta Barat • DKI Jakarta • Indonesia
TEKTRONIX – TLA7000

TEKTRONIX – TLA7000

Network Analyzer
Product Description The modular TLA7000 Logic Analyzer Series provides the speed and flexibility you need to capture logic detail on today’s fastest microprocessors and memory designs. Pinpoint the source of elusive errors and gain the visibility you want with large easy-to-read displays, fast data throughput, and time-correlated views of analog and digital signals through the same probe. Specification Features Benefits MagniVu™ acquisition Avoid missing events completely in either timing or state acquisition mode with higher sampling resolution (up to 20 ps) on all channels. iCapture™ multiplexing Eliminate double probing with simultaneous digital and analog acquisition through a single logic analyzer probe. Flagging the glitch Remove the need to manually search all channels using exclusive ability to show both the time and channel where the glitch occurred. TS/TH violation triggering Eliminate the time consuming and complex task of monitoring the circuit’s outputs with real-time violation triggering that automatically acquires intermittent setup and hold violations. iView™ display Gain complete system visibility with time-correlated, integrated analog and digital data on one display. iVerify™ analysis Quickly find signal integrity issues with multi-channel bus analysis using oscilloscope-generated eye diagram. Automated measurements Easily summarize your design’s performance with sophisticated measurements such as: frequency, period, pulse width, duty cycle, and edge count. Drag & drop triggers Quickly isolate events through simple and intuitive trigger setup. Triggers include: Channel Edge, Channel Value, Bus Value, Multi-Group Value, Glitch, Setup and Hold Violation, or Trigger on Anything.
Harga
Hubungi Kami
Min. Order
1 buah

  • PT. MADIRI MULTI KREASI. No.Tlp : 021-6230 5566/ 0813 1600 6033 / 0812 9436 9944

    Jakarta Barat • DKI Jakarta • Indonesia
TEKTRONIX – TLA6400

TEKTRONIX – TLA6400

Network Analyzer
Product Description The affordable TLA6400 Series of logic analyzers offer the performance needed to debug, validate, and optimize the functionality of your digital system. The TLA6400 Series also provides a comprehensive set of signal integrity debug tools that allow you quickly isolate, identify, and characterize elusive and hard-to-find problems. Add a broad range of support for today’s applications, and you have the ideal tool to help you meet all of the debug challenges of today’s digital designs. Specification Features Benefits 40 ps Resolution MagniVu™ acquisition mode enabled you to accurately see signal relationships in your system. State Acquisition Sample your fastest synchronous buses with clock rates up to 667 MHz and data rates up to 1333 Mb/s. 15 in. Display With the large display and optional touch screen, you can see more of your data and navigate efficiently through it. 4 Models Choose 34, 68, 102 or 136 channels and up to 64 Mb record length which offers flexible solutions to fit any budget. Drag-and-Drop Triggering Simply drag any one of eight different trigger types from a table onto the waveform and the logic analyzer will automatically set up the trigger conditions, eliminating errors, improving repeatability, and saving time. Drag-and-Drop Measurements Simply drag an icon from the measurement toolbar and drop it onto your signal of interest and get a table of results. Saves time, removes complexity, and reduces measurement uncertainty. Glitch Trigger and Storage Allows you to trigger on and highlight potential signal integrity problems. Not only can the TLA6400 Series trigger on the problem, but by highlighting suspected problems in red, you will be able to easily determine which signals you need to further investigate. iCapture Route the suspected signal to the analog output of the TLA6400 Series using the exclusive Tektronix iCapture feature. This eliminates the need to add an additional oscilloscope probe, minimizing potential loading issues and further reducing time to debug. iView Time-correlated view of both logic analyzer and oscilloscope data to trace the signal integrity  problem across the digital and analog domains.
Harga
Hubungi Kami
Min. Order
1 buah

  • PT. MADIRI MULTI KREASI. No.Tlp : 021-6230 5566/ 0813 1600 6033 / 0812 9436 9944

    Jakarta Barat • DKI Jakarta • Indonesia
Hioki PW3196-20, Clamp On Power HiTester

Hioki PW3196-20, Clamp On Power HiTester

Network Analyzer
CALL:A.WIHARTA081294124885085778084789087784022201Karya Mandiri Instrument indonesia adalah supplier peralatan laboratorium baik eletronik maupun mekanik, serta berbagai macam instrument measurement, dengan didukung dari berbagai macam merk dari negara negara Eropa, US, dan beberapa negara di Asia seperti Korea, Japan dan Taiwan. Instrument yang kami sediakan seperti : Anemometer, Analitical Balance, Spectrophotometer, pHmeter, Laser survey, Micropipette, Peristaltic Pump, Flame photometer, Water bath heating cooling, Colorimeter, Water Strirer, Viscometer. Freezers, Refractometer, Polarimeter, Sound Level meter, Tachometer. Dll Kami juga menerima jasa service dan kalibrasi untuk peralatan laboratorium sesuai kemampuan kami.   Basic specifications ( Accuracy guaranteed for 1 year) Measurement line & number of circuits Single-phase 2-wires ( 4 circuits) , Single-phase 3-wires ( 2 circuits) , Three-phases 3-wires ( 2 or 1 circuit) , and Three-phases 4-wires ( 1 circuit) Note: 50 or 60 Hz, and that share the same voltage line Measurement items Voltage, Current, Active/ reactive/ apparent power, Active/ reactive power integration, Power factor, Frequency, Harmonic waveform value Voltage ranges 150.00 V to 600.00 V AC, 3 ranges Current ranges 500.00 mA to 5.0000 kA AC ( depends on current sensor in use) Power ranges 75.000 W to 900.00 kW ( depends on combination of voltage, current range, and measurement line) Basic accuracy AC Voltage: ± 0.2 % rdg. ± 0.1 % f.s. AC Current: ± 0.2 % rdg. ± 0.1 % f.s. + current sensor accuracy Active power: ± 0.2 % rdg. ± 0.1 % f.s. + current sensor accuracy ( at power factor = 1) CLAMP ON SENSOR 9661: ± 0.3 % rdg. ± 0.01 % f.s. ( different from each model) Measurement method Digital sampling, PLL synchronization or 50/ 60 Hz fixed clock Basic accuracy Active power: ± 0.2% rdg. ± 0.1% f.s. + clamp-on sensor accuracy ( at 45 to 66 Hz) Display refresh rate 2 times / sec ( except when using a PC card while accessing the internal memory, or when performing RS-232C communications) Data save interval Standard interval: 1 sec to 30 sec, 1 minute to 60 minutes, 13 selects Fast interval: A single waveform, or 0.1, 0.2, or 0.5 sec ( at instant value only) Frequency characterristics Fundamental waveforms up to the 50th order ± 3% f.s. + measurement accuracy ( of a 45 to 66 Hz fundamental waveform) Other functions Error connect check, language selection, display hold, setting backup, power shut off management, key lock, [ 3169-21 only] D/ A output 4 channels, ± 5 V DC f.s.) Power supply 100 to 240 V AC, 50/ 60 Hz, 30 VA max. Dimensions, mass 210 mm ( 8.27 in) W × 160 mm ( 6.30 in) H × 60 mm ( 2.36 in) D, 1.2 kg ( 42.3 oz) Supplied accessories VOLTAGE CORD L9438-53 × 1 ( Black/ Red/ Yellow/ Blue) , Power cord × 1, Instruction Manual × 1, Quick Start Manual × 1, CD-R × 1 ( RS-232C interface operating manual) × 1, Input cord label × 1, CONNECTION CABLE 9441 × 1 ( for the 3169-21 only)
Harga
Hubungi Kami
Min. Order
0 buah

  • Karya Mandiri Instrument Indonesia

    Jakarta Timur • DKI Jakarta • Indonesia
Hioki Power Quality Analyzer PW3198-90

Hioki Power Quality Analyzer PW3198-90

Network Analyzer
CALL:A.WIHARTA081294124885085778084789087784022201Karya Mandiri Instrument indonesia adalah supplier peralatan laboratorium baik eletronik maupun mekanik, serta berbagai macam instrument measurement, dengan didukung dari berbagai macam merk dari negara negara Eropa, US, dan beberapa negara di Asia seperti Korea, Japan dan Taiwan. Instrument yang kami sediakan seperti : Anemometer, Analitical Balance, Spectrophotometer, pHmeter, Laser survey, Micropipette, Peristaltic Pump, Flame photometer, Water bath heating cooling, Colorimeter, Water Strirer, Viscometer. Freezers, Refractometer, Polarimeter, Sound Level meter, Tachometer. Dll Kami juga menerima jasa service dan kalibrasi untuk peralatan laboratorium sesuai kemampuan kami.   Basic Specifications Power quality measurement standard compliance IEEE 1159, IEC 61000-4-30 Ed. 2 Class A Maximum recording period 1 month ( with repeat function on: 55 weeks) Maximum number of recordable events 1, 000 ( with repeat function on: 55, 000) Interfaces SD card slot ( for writing data to an SD memory card) , LAN ( for remote operation and downloading of recorded data) , USB ( for downloading of recorded data) , RS-232C ( for printer and GPS connectivity) Power supply Rated supply voltage: 12 V DC ( maximum rated power: 35 VA) AC ADAPTER Z1002, BATTERY PACK Z1003 Continuous battery-powered operating time Approx. 180 min. ( with BATTERY PACK Z1003) Dimensions Approx. 300 ( W) × 211 ( H) × 68 ( D) mm ( excluding protruding parts) Weight Approx. 2.57 kg ( including BATTERY PACK Z1003) Measurement Specifications 1. Time Plot Voltage items RMS voltage, waveform peak, harmonic, harmonic phase angle, inter-harmonics, high-order harmonic component, total harmonic distortion factor, unbalance factor ( negative-phase and zero-phase) , DC voltage, frequency ” V10 Current items RMS current, waveform peak, harmonic, harmonic phase angle, inter-harmonics, high-order harmonic component, total harmonic distortion factor, unbalance factor ( negative-phase and zero-phase) , DC current, K factor Power items Active power, reactive power, apparent power, harmonic power, harmonic voltage-current phase difference, active integral power, reactive integral power, power factor 2. Event acquisition Transients, swells, dips, interruptions, frequency, rush current, voltage waveform comparison, timer, external, and other combinations of the time series item events listed above Input Specifications Measurement line 1-phase 2-wire, 1-phase 3-wire, 3-phase 3-wire, 3-phase 4-wire Plus 1 channel in addition to the above measurement lines Measurement frequency Basic frequency: 50/ 60/ 400 Hz Transient overvoltage: 2 MHz sampling Harmonic measurement Orders 0 ( DC) to 50 ( 2.5 kHz or 3 kHz) Voltage measurement range Voltage measurement: 600.00 Vrm Transient overvoltage measurement: ± 6.0000 kV peak Current measurement range Load current measurement With 9694 sensor: 5.0000/ 50.000 Arms With 9660 sensor: 50.000/ 100.00 Arms With 9661 sensor: 50.000/ 500.00 Arms With 9667 sensor: 50.000/ 500.00 A, 500.00 A/ 5.0000 kArms With 9669 sensor: 100.00 A/ 1.0000 kArms Leak current measurement With 9675/ 9657-10 sensor: 500.00 mA/ 5.0000 Arms Measurement accuracy ( 50 Hz/ 60 Hz measurement) RMS voltage ± 0.1% rdg. RMS current ± 0.2% rdg. ± 0.1% f.s. + current sensor accuracy Active power ± 0.2% rdg. ± 0.1% f.s. + current sensor accuracy
Harga
Hubungi Kami
Min. Order
0 buah

  • Karya Mandiri Instrument Indonesia

    Jakarta Timur • DKI Jakarta • Indonesia
Hioki 3197 Power Quality Analyzer

Hioki 3197 Power Quality Analyzer

Network Analyzer
CALL:A.WIHARTA081294124885085778084789087784022201Karya Mandiri Instrument indonesia adalah supplier peralatan laboratorium baik eletronik maupun mekanik, serta berbagai macam instrument measurement, dengan didukung dari berbagai macam merk dari negara negara Eropa, US, dan beberapa negara di Asia seperti Korea, Japan dan Taiwan. Instrument yang kami sediakan seperti : Anemometer, Analitical Balance, Spectrophotometer, pHmeter, Laser survey, Micropipette, Peristaltic Pump, Flame photometer, Water bath heating cooling, Colorimeter, Water Strirer, Viscometer. Freezers, Refractometer, Polarimeter, Sound Level meter, Tachometer. Dll Kami juga menerima jasa service dan kalibrasi untuk peralatan laboratorium sesuai kemampuan kami.   Measurement lines Single-phase/ two-wires, Single-phase/ three-wires, Three-phase/ three-wires, Three-phase/ four-wires Measurement line frequency Auto-detect ( 50Hz/ 60Hz) Voltage range 600.0V AC Current ranges Manually switch-able from 2 range sets according to Clamp sensor 500.0mA / 5.000A/ 50.00A / 10.00A / 100.0A / 500.0A / 1.000kA / 5.000 kA Measurement items Impulsive voltage quality : Transient overvoltage ( Impulse) , RMS voltage quality : Voltage swell, Voltage dips, Voltage interruption, Power quality : Frequency, Voltage, Current, Current peak, Active/ Reactive/ Apparent power, Power factor ( displaced power factor) , Three phase quality : Voltage unbalance ratio, Current unbalance ratio, Harmonic quality ( Up to 50th order) : Harmonic voltage, Harmonic current, Harmonic power, Harmonic voltage/ current phase angle, Total harmonic voltage distortion, Total harmonic current distortion ( THD-F, THD-R) , Interval settings AUTO / 1 / 5 / 10 / 15 / 30 / 60 minutes Maximum record-able period 125 Days with internal non-volatile memory of 4MB-stored data will not be deleted upon power OFF; partition memory into 4 segments for maximum 31 days of recording each Internal memory 4 MB PC Interface USB Ver.2.0 Power supply 9418-15 AC ADAPTER or 9459 BATTERY PACK Dimensions, mass 128W × 246 H × 63 D mm, 1.2 kg with battery pack Accessories Voltage cords 9438-05 ( 1set) , BATTERY PACK 9459 ( 1) , AC ADAPTER 9418-15 ( 1) , USB Cable ( 1) , Basic PC Software CD-R ( 1) , Carrying Case ( 1) , Strap ( 1) - See more at:
Harga
Hubungi Kami
Min. Order
0 buah

  • Karya Mandiri Instrument Indonesia

    Jakarta Timur • DKI Jakarta • Indonesia
  • dari 4 halaman