Hi, Guest!
  • dari 4 halaman

Jual Beli Produk Resistor

Fluke 789 ProcessMeter™ With 250 Ohm HART Resistor

Fluke 789 ProcessMeter™ With 250 Ohm HART Resistor

Resistor
CALL:A.WIHARTA081294124885085778084789087784022201Karya Mandiri Instrument indonesia adalah supplier peralatan laboratorium baik eletronik maupun mekanik, serta berbagai macam instrument measurement, dengan didukung dari berbagai macam merk dari negara negara Eropa, US, dan beberapa negara di Asia seperti Korea, Japan dan Taiwan. Instrument yang kami sediakan seperti : Anemometer, Analitical Balance, Spectrophotometer, pHmeter, Laser survey, Micropipette, Peristaltic Pump, Flame photometer, Water bath heating cooling, Colorimeter, Water Strirer, Viscometer. Freezers, Refractometer, Polarimeter, Sound Level meter, Tachometer. Dll Kami juga menerima jasa service dan kalibrasi untuk peralatan laboratorium sesuai kemampuan kami.   The Fluke 787 was the first tool to combine a DMM and a loop calibrator to give process technicians double the power in one tool. Now it' s even better, the range is extended with the new Fluke 789 – the ultimate loop calibration multimeter. The Fluke 789 has a 24-Volt loop supply reducing the need for taking a separate power supply when doing offline transmitter testing. And with its built-in, selectable 250-Ohm Hart® resistor, it also eliminates the need to carry a separate resistor with you. Now process technicians can do a lot more while carrying a lot less. Features of the Fluke 789 24 V Loop power supply Very large dual display Enhanced backlight with 2 brightness settings 1200 Ohm drive capability on mA source HART mode setting with loop power and a built-in 250 ohm resistor 0% and 100 % buttons to toggle between 4 and 20 mA sourcing for a quick span check Externally accessible fuses for easy replacement Infrared-port to process data in FlukeView Forms ( V2.1) software Fluke 789 features that are also included in the Fluke 787 Precision 1000 V, 440 mA True-RMS digital Multimeter 0.1% dc voltage accuracy 0.05% dc current accuracy Frequency measurement to 20 kHz Min/ Max/ Average/ Hold/ Relative modes Diode Test and Continuity Beeper Simultaneous mA and % of scale readout 20 mA DC current source / loop calibrator / simulator Manual Step ( 100% , 25% , Coarse, Fine) plus Auto Step and Auto Ramp Externally accessible battery for easy battery changes Safety Conformance Meets 1000 Volt EN61010-1 CAT III standards and 600 Volt EN61010-1 CAT IV standards.
Harga
Hubungi Kami
Min. Order
0 buah

  • Karya Mandiri Instrument Indonesia

    Jakarta Timur • DKI Jakarta • Indonesia
Kyoritsu – 4300

Kyoritsu – 4300

Resistor
Product Description KEW 4300 is simplified earth resistance tester (based on 2-pole method) that can be used for various distribution lines and electrical appliances and it also can measure AC/DC voltage. (As for AC Voltages, true rms values can be obtained.) 200/2000Ω (2 ranges): auto-ranging. Warning buzzer triggered at 100Ω or less. LED lights up when a large earth voltage is detected. Live circuit warning when 30V or higher voltage is detected. (KEW 4300 detects voltage even when measuring resistances.) LED light for illuminating measurement points. (It turns on/off automatically in relation to the ambient brightness.) Small test current (max 2mA) not triggering RCD. Specification Earth resistance ranges 200.0/2000Ω (Auto ranging)±3%rdg±5dgt Voltage ranges AC: 5.0 – 300.0V (45 – 65Hz)±1%rdg±4dgtDC: ±5.0 – 300.0V±1%rdg±8dgt Applicable standards IEC 61010-1 CAT III 300V pollution degree 2IEC 61010-031, 61557-1, -5IEC 61326-1, 2-2, IEC 60529 (IP40) Withstand voltage 3540V AC for 5 seconds(between the electrical circuit and enclosure) Power source Size AA alkaline battery × 2pcs Dimensions 232(L) × 51(W) × 42(D)mm Weight 220g approx. (including battery) Accessories 7248 (Test lead with Alligator clip and Flat test probe)8072 (CAT II Standard prod)8253 (CAT III Standard prod)8017 (Extension prod long)9161 (Carrying case)Instruction manual, LR6 (AA) × 2  
Harga
Hubungi Kami
Min. Order
1 buah

  • PT ANDALAN BANGUN SEJAHTERA

    Jakarta Pusat • DKI Jakarta • Indonesia
Kyoritsu – 4106

Kyoritsu – 4106

Resistor
Product Description High test current up to 80mA yielding resolution of 0.001Ω on 2Ω range. Advanced Filtering method (based on FFT Fast Fourier Transform) reduces noise interference for obtaining stable measurements. Automatic andManual selection of the Test Current Frequency in four bands (94/105/111/128Hz). In Automatic mode, KEW 4106 will select the most suitable Frequency. Several sub-results can be shown on the display: Resistance of the Auxiliary Earth Spikes, Frequency of Test Current, Voltage and Frequency of Interference (noise), Residual Resistance Rk, etc. Warning for excessive noise and high Auxiliary Earth Spikes resistance. Large Graphic Display with backlight for readings in poorly illuminated areas. Up to 800 measurement results can be saved in the memory and recalled on the display. The stored results can be transferred to a PC using the “KEW Report” software and a USB adaptor (Model 8212-USB) which are included. Robust design with IP54 protection. Specification Function Range Resolution Measuring range Accuracy Earth resistanceRe(Rg atρ measurement) 2Ω 0.001Ω 0.03 – 2.099Ω |±2%rdg±0.03Ω 20Ω 0.01Ω 0.03 – 20.99Ω |±2%rdg±5dgt (*1) 200Ω 0.1Ω 0.3 – 209.9Ω 2000Ω 1Ω 3 – 2099Ω 20kΩ 10Ω 0.03k – 20.99kΩ 200kΩ 100Ω 0.3k – 209.9kΩ Auxiliary earth resistanceRh, Rs       8% of Re+Rh+Rs Earth resistivityρ 2Ω 0.1Ω•m – 1Ω•mAutoranging 0.2 – 395.6Ω•m ρ=2×π×a×Rg (*2) 20Ω 0.2 – 3956Ω•m 200Ω 20 – 39.56kΩ•m 2000Ω 0.2 – 395.6kΩ•m 20kΩ 2.0 – 1999kΩ•m 200kΩ Series interference voltageUst (A.C only) (*3) 50V 0.1V 0 – 50.9Vrms |±2%rdg±2dgt (50/60Hz) |±3%rdg±2dgt (40 – 500Hz) FrequencyFst Autoranging 0.1Hz1Hz 40Hz – 500Hz |±1%rdg±2dgt Measuring method Earth resistance: Fall-of-potential method (currents and voltages measured via the Probes)Measurement method of Earth Resistivity (ρ): Wenner 4-pole methodSeries interference voltage (earth voltage): RMS Rectifier (between the E-S Terminals) Memory capacity 800 data Communication Interface Model 8212-USB Optical Adaptor LCD Dot-matrix 192×64 monochrome Over-range Indication “OL” Overload Protection between E-S(P) and between E-H(C) terminals AC280V / 10 sec. Withstand voltage between the electrical circuit and enclosure AC3540V(50/60Hz) / 5 sec. Applicable standards IEC 61010-1 CAT III 300V, CAT IV 150V Pollution degree 2IEC 61010-031, IEC 61557-1, 5, IEC 61326-1 (EMC), IEC 60529 (IP54) Power source DC12V : sizeAA manganese dry battery (R6) × 8(Auto power off: approx. 5 minutes) Dimensions 167(L) × 185(W) × 89(D) mm Weight approx. 900g (including batteries) Accessories 7229A (Earth precision measurement),7238A (Simplified measurement test leads),8032 (Auxiliary earth spikes [2 spiks/set])×2 sets (4 spikes in total),8200-04 (Cord reel [4 pcs])×1 set,8212-USB (USB adaptor with “KEW Report(Software)”),9121 (Shoulder strap),9125 (Carrying case),R6 × 8, Instruction manual, Calibration certificate Optional 8212-RS232C (RS232C adaptor with “KEW Report(Software)”)  
Harga
Hubungi Kami
Min. Order
1 buah

  • PT ANDALAN BANGUN SEJAHTERA

    Jakarta Pusat • DKI Jakarta • Indonesia
Kyoritsu – 4200

Kyoritsu – 4200

Resistor
Product Description The earth resistance from 0.05 to 1500Ω can be measured without the auxiliary earth spikes. (The Multiple Earthing System.) True RMSAccurate true RMS readings of AC current including distorted waveform from 1mA to 30.0A Noise Check FunctionA function to detect current, which effects on an earth resistance measurement and display “NOISE” mark on the LCD. Memory functionSave and display up to 100 measurement data. Data hold function / Buzzer function / Back light functionCompliant with Safety Standards of IEC 61010-1 : CAT IV 300V Pollution degree2 Specification Function Range Resolution Measuring range Accuracy Earth resistance Auto range 20Ω 0.01Ω* 0.00 – 20.99Ω |±1.5%±0.05Ω 200Ω 0.1Ω 16.0 – 99.9Ω |±2%±0.5Ω 100.0 – 209.9Ω |±3%±2Ω 1500Ω 1Ω 160 – 399Ω |±5%±5Ω 400 – 599Ω |±10%±10Ω 10Ω 600 – 1580Ω — AC current(50Hz / 60Hz)Auto range 100mA 0.1mA 0.0 – 104.9mA |±2%±0.7mA 1000mA 1mA 80 – 1049mA |±2% 10A 0.01A 0.80 – 10.49A 30A 0.1A 8.0 – 31.5A Operating system Earth resistance function : Constant voltage injection,Current detection,(Frequency : Approx.2400Hz)Dual Integration AC current function : Successive Approximation Over-range indication “OL” is displayed when input exceeds the upper limit of a measuring range Response time Approx.7 seconds (Earth resistance)Approx.2 seconds (AC current) Sample rate Approx. 1 times per second Power source DC6V : R6 (sizeAA manganese battery) × 4pcs,or LR6 (sizeAA alkaline battery) × 4pcs Current consumption Approx. 50mA (max. 100mA) Measurement time Approx. 12 hours (when R6 is used)Approx. 24 hours (when LR6 is used) Auto power-off Turns power off about 10 minutes after the last button operation. Applicable standards IEC 61010-1 : 2001 (CAT IV 300V Pollution degree2) Withstand voltage AC5320Vrms / 5 secondsBetween the Transformer jaws fitted parts and Case enclosure(except for jaws) Conductor size Approx. 32mm max. Dimension 246(L) × 120(W) × 54(D)mm Weight Approx. 780g (including batteries) Accessories Battery R6 (AA) × 4, Instruction manual8304 (Resister for operation check)9166 (Hard case)
Harga
Hubungi Kami
Min. Order
1 buah

  • PT ANDALAN BANGUN SEJAHTERA

    Jakarta Pusat • DKI Jakarta • Indonesia
Kyoritsu – 4105A

Kyoritsu – 4105A

Resistor
Product Description Dust and drip proof.(designed to IEC 529 IP54) In addition to the facility for precision measurement, test leads for simplified two wire measuring system also supplied as standard accessories. (unit can be hung from the neck for simplified measurement) Designed to meet IEC 61010-1 safety standard. Capable of measuring earth voltage. Automatic warning when resistance of auxiliary earth spikes is in excess of tolerance. Small and lightweight. Shock resistant new case material. 2mA measuring current permits earth resistance tests without tripping earth leakage current breakers in the circuit under test. Specification MeasurementRanges Earth Resistance: 0 – 20Ω/0 – 200Ω/0 – 2000ΩEarth Voltage [50,60Hz]: 0 – 200V AC Accuracy Earth Resistance: ±2%rdg±0.1Ω (20Ωrange)|±2%rdg±3dgt (200Ω/2000Ωrange)Earth Voltage: ±1%rdg±4dgt Overload Protection Earth Resistance: 280V AC for 10 secondsacross 2 of the 3 terminalsEarth Voltage: 300V AC for 1 minute Safety Standard IEC 61010-1 CAT III 300V Pollution Degree 2, IEC 61557 Applicable Standards IEC 60529 IP54 Withstand Voltage 3700V AC for 1 minute Power Source R6 (AA) (1.5V) × 6 Dimensions 105(L) × 158(W) × 70(D)mm Weight 550g approx. Accessories 7095A (Earth resistance test leads) × 1set(red-20m, yellow-10m, green-5m)8032 (Auxiliary earth spikes) × 1set7127A (Simplified measurement probe) × 1setR6 (AA) × 6Neck strapInstruction Manual   Carrying Case : 9084 (Soft case)   : 9165 (Hard case) Optional 7100A (Precision measurement cord set)  
Harga
Hubungi Kami
Min. Order
1 buah

  • PT ANDALAN BANGUN SEJAHTERA

    Jakarta Pusat • DKI Jakarta • Indonesia
  • dari 4 halaman